EasyBand® Plus-Mini 200μm Reduced Diameter Bending Insensitive Single-mode Fibre
Classification:
EasyBand® Plus-Mini fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design.
Cotnact:
Details Introduction
EasyBand® Plus-Mini fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design. EasyBand® Plus-Mini fibre keeps the same glass part size as standard 245μm fibre (bare glass part diameter is still 125μm) and has the same MFD, cutoff and other optical parameters as 245μm fibre such as EasyBand® Plus, and it inherits almost all the advantages of EasyBand® Plus standard 245μm diameter G.657.A2 fibre.
Applications
• All types of fibre cables with different structures
• High performance optical network operating in O-E-S-C-L band
• High speed optical routes for Fibre-to-the-Home networks
• Cables with extreme low bending requirements
• Small-sized fibre cable and optical component
Product standards
YOFC EasyBand® Plus-Mini fibre fully complies with ITU-T G.652.D/G.657.A1/G.657.A2/G.657.B2 specifications. It is also comprehensively optimized for use in the whole telecom wavelength window (1260 nm-1625 nm).
Characteristics
• Reduced cable size and weight for micro cable
• More suitable for application in downsized optical fibre devices
• Reduce network deployments cost and total cost of ownership
• Compatible with standard cleaving and stripping tools
• Similar settings of the fusion splice program with that of G.652 fibre
• All bands utilization, from O to L band and ready for future systems evolutions
Parameter
Characteristics |
Conditions |
Specified values |
||
Optical Specifications |
||||
Attenuation |
1310nm |
≤0.35 |
||
|
1383nm(after H2-aging) |
≤0.35 |
||
|
1550nm |
≤0.21 |
||
|
1625nm |
≤0.23 |
||
Attenuation vs. Wavelength Max. α difference |
1285-1330nm, in reference to 1310nm |
≤0.03 |
||
|
1525-1575nm, in reference to 1550nm |
≤0.02 |
||
|
1460-1625nm, in reference to 1550nm |
≤0.04 |
||
Zero Dispersion Wavelength (λ0) |
-- |
1300-1324 |
||
Zero Dispersion slpoe(S0) |
-- |
≤0.092 |
||
PMD |
Maximum Individual Fibre |
-- |
≤0.2 |
|
|
Link Design Value(M=20,Q=0.01%) |
-- |
≤0.1 |
|
|
Typical Value |
-- |
0.04 |
|
Cable Cut-off Wavelength (λCC) |
-- |
≤1260 |
||
Mode Field Diameter(MFD) |
1310nm |
8.4-9.2 |
||
|
1550nm |
9.3-10.3 |
||
Effective Group Index(Neff ) |
1310nm |
1.466 |
||
|
1550nm |
1.467 |
||
Point Discontinuities |
1310nm |
≤0.05 |
||
|
1550nm |
≤0.05 |
||
Geometrical Specifications |
||||
Cladding Diameter |
-- |
125.0±0.7 |
||
Cladding Non-Circularity |
-- |
≤0.7 |
||
Coating Diameter |
-- |
190-210 |
||
Coating/Cladding Concentricity Error |
-- |
≤10 |
||
Coating Non-Circularity |
-- |
≤6 |
||
Core/Cladding Concentricity Error |
-- |
≤0.5 |
||
Curl(radius) |
-- |
≥4 |
||
Delivery Length |
-- |
Up to 50.4 |
||
Environmental Specifications |
1310nm, 1550nm & 1625nm |
|||
Temperature Dependence Induced Attenuation |
-60℃ to +85℃ |
≤0.05 |
||
Temperature-Humidity Cycling Induced Attenuation |
-10°C to +85°C, 98% RH |
≤0.05 |
||
Watersoak Dependence Induced Attenuation |
23°C,for 30 days |
≤0.05 |
||
Damp Heat Dependence Induced Attenuation |
85°C and 85% RH,for 30 days |
≤0.05 |
||
Dry Heat Aging |
85℃,for 30 days |
≤0.05 |
||
Mechanical Specifications |
||||
Proof Test |
-- |
≥9.0 |
||
|
-- |
≥1.0 |
||
|
-- |
≥100 |
||
Macro-bend Induced Attenuation |
10 Turn Around a Mandrel of 15 mm Radius |
1550 |
≤0.03 |
|
|
10 Turn Around a Mandrel of 15 mm Radius |
1625 |
≤0.1 |
|
|
1 Turn Around a Mandrel of 10 mm Radius |
1550 |
≤0.1 |
|
|
1 Turn Around a Mandrel of 10 mm Radius |
1625 |
≤0.2 |
|
|
1 Turn Around a Mandrel of 7.5 mm Radius |
1550 |
≤0.5 |
|
|
1 Turn Around a Mandrel of 7.5 mm Radius |
1625 |
≤1.0 |
|
Dynamic Fatigue Parameter (nd) |
-- |
≥20 |
Documents
Previous Page
Keyword:
EasyBand® Plus-Mini 200μm Reduced Diameter Bending Insensitive Single-mode Fibre
Production
Related Products
Message consultation
We will surprise you with a gift as soon as we receive your message.
Contact Information
Add: 9th Floor, Building B, Optics Valley Times Square, No. 111 Guanshan Avenue, Donghu New Technology Development Zone, Wuhan