• 1 (6) (2).png
  • 2 (10) (1).png
  • 3 (7) (1).png

165μm

Reduced Diameter Bending Insensitive Fibre

Classification:

165μm fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design, furthermore,


Details Introduction


 165μm fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design, furthermore, by reducing the outer clad’s thickness, 165um fibre’s glass part diameter is only 80 um and has the similar MFD to standard G.657.B3 fibre. 165 um reduced diameter bending insensitive fibres delivers the outstanding bending performance to a 5 mm radius for demanding applications while maintaining compatible with conventional G.652.D and G.657 fibres. It is an excellent choice for application where small size, small bend radii may be encountered.

Applications

Small-sized optical component

Characteristics

Outstanding bending performance and compatible with G 652.D and G.657 fibres.

Proof-tested to 200 KPSI to ensure reliability.

56% less CSA than conventional 250 μm coated fibre enabling smaller size optical component.

Parameter


Characteristics

Conditions

Optical Characteristics

Attenuation

1550 nm

Zero Dispersion Wavelength (λ0)

--

Zero dispersion Slope (S0)

--

Fibre Cut-off Wavelength

--

Mode Field Diameter (MFD)

1550 nm

Geometrical Characteristics

Cladding Diameter

--

Cladding Non-Circularity

--

Cladding Non-Circularity

--

Coating/Cladding Concentricity Error

--

Coating Non-Circularity

--

Core/Cladding Concentricity Error

--

Curl (radius)

--

Delivery Length

--

Environmental Characteristics 1550 nm & 1625 nm

Temperature Dependence Induced Attenuation

-60℃ to +85℃

Temperature-Humidity Cycling Induced Attenuation

-10°C to +85°C, 98% RH

Watersoak Dependence Induced Attenuation

23°C, for 30 days

Damp Heat Induced Attenuation

85°C and 85% RH, for 30 days

Dry Heat Aging

85℃, for 30 days

Mechanical Specifications

Proof Test

--

Macro-bend Induced Loss

1 Turn Around a Mandrel of 5 mm Radius

1550 nm

 

 

1625 nm

 

1 Turn Around a Mandrel of 7.5 mm Radius

1550 nm

 

 

1625 nm

 

1 Turn Around a Mandrel of 10 mm Radius

1550 nm

 

 

1625 nm

Dynamic Fatigue Parameter (nd)

--

Tensile Strength

F15%

 

F50%

Documents



Keyword:

Reduced Diameter Bending Insensitive Fibre

Production


Production
Production
Production
Production
Production
Production

Message consultation


We will surprise you with a gift as soon as we receive your message.

Contact Information

WhatsApp: +86 13307141064

Email: sales@fibercore.cn

Add: 9th Floor, Building B, Optics Valley Times Square, No. 111 Guanshan Avenue, Donghu New Technology Development Zone, Wuhan

We will surprise you with a gift as soon as we receive your message.

Submit