165μm
Reduced Diameter Bending Insensitive Fibre
Classification:
165μm fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design, furthermore,
Cotnact:
Details Introduction
165μm fibre realized reduced fibre outer diameter with excellent bending performance thanks to its bending insensitive fibre design, furthermore, by reducing the outer clad’s thickness, 165um fibre’s glass part diameter is only 80 um and has the similar MFD to standard G.657.B3 fibre. 165 um reduced diameter bending insensitive fibres delivers the outstanding bending performance to a 5 mm radius for demanding applications while maintaining compatible with conventional G.652.D and G.657 fibres. It is an excellent choice for application where small size, small bend radii may be encountered.
Applications
Small-sized optical component
Characteristics
Outstanding bending performance and compatible with G 652.D and G.657 fibres.
Proof-tested to 200 KPSI to ensure reliability.
56% less CSA than conventional 250 μm coated fibre enabling smaller size optical component.
Parameter
Characteristics |
Conditions |
||
Optical Characteristics |
|||
Attenuation |
1550 nm |
||
Zero Dispersion Wavelength (λ0) |
-- |
||
Zero dispersion Slope (S0) |
-- |
||
Fibre Cut-off Wavelength |
-- |
||
Mode Field Diameter (MFD) |
1550 nm |
||
Geometrical Characteristics |
|||
Cladding Diameter |
-- |
||
Cladding Non-Circularity |
-- |
||
Cladding Non-Circularity |
-- |
||
Coating/Cladding Concentricity Error |
-- |
||
Coating Non-Circularity |
-- |
||
Core/Cladding Concentricity Error |
-- |
||
Curl (radius) |
-- |
||
Delivery Length |
-- |
||
Environmental Characteristics 1550 nm & 1625 nm |
|||
Temperature Dependence Induced Attenuation |
-60℃ to +85℃ |
||
Temperature-Humidity Cycling Induced Attenuation |
-10°C to +85°C, 98% RH |
||
Watersoak Dependence Induced Attenuation |
23°C, for 30 days |
||
Damp Heat Induced Attenuation |
85°C and 85% RH, for 30 days |
||
Dry Heat Aging |
85℃, for 30 days |
||
Mechanical Specifications |
|||
Proof Test |
-- |
||
Macro-bend Induced Loss |
1 Turn Around a Mandrel of 5 mm Radius |
1550 nm |
|
|
|
1625 nm |
|
|
1 Turn Around a Mandrel of 7.5 mm Radius |
1550 nm |
|
|
|
1625 nm |
|
|
1 Turn Around a Mandrel of 10 mm Radius |
1550 nm |
|
|
|
1625 nm |
|
Dynamic Fatigue Parameter (nd) |
-- |
||
Tensile Strength |
F15% |
||
|
F50% |
Documents
Previous Page
Next Page
Keyword:
Reduced Diameter Bending Insensitive Fibre
Production
Related Products
Message consultation
We will surprise you with a gift as soon as we receive your message.
Contact Information
Add: 9th Floor, Building B, Optics Valley Times Square, No. 111 Guanshan Avenue, Donghu New Technology Development Zone, Wuhan